Image may not exactly match the product.

Tripp Lite SMART2600RM2U Smart Pro 2600VA UPS Backup RM/TWR 9 Outlet

SKU:
SMART2600RM2U
Shipping:
$50.00 (Fixed Shipping Cost)
$2,570.26 $1,474.13
(You save $1,096.13 )

Image may not exactly match the product.

Out of Stock.

Request a quote for re-stock information.

$2,570.26 $1,474.13
(You save $1,096.13 )
Availability:
Currently out of stock, pre-order may be available

Condition:
New
Warranty Information
2 Years

Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.

Share:

2600VA UPS Smart Pro Rack/Tower Line-Interactive 9 outlet

 

 

Key Features

  • SmartPro line interactive UPS system is ideal for voice, data, medical and industrial networking applications
  • High 96% line-power efficiency rating reduces energy consumption and BTU heat output
  • Line interactive Automatic Voltage Regulation (AVR) offers two levels of voltage boost during brownouts and one level of voltage cut during overvoltages
  • Maintains continuous operation through blackouts, voltage fluctuations and surges
  • Corrects line voltage conditions as low as 83V and as high as 145 back to 120V nominal values
  • Standard internal battery set offers 12 minutes at full load and 4 minutes at full load
  • Optional BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external rack/tower battery packs enable extended runtime operation
  • Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
  • Compact form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 19 inches
  • Ships with all mounting accessories for 4 post rackmount installation
  • Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation
  • Optional 2-9USTAND accessory enables small-footprint upright tower placement
  • Network interfaces support simultaneous communications via built-in USB, DB9 serial and SNMPWEBCARD slot
  • HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
  • Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, with the built-in ability to shutdown any number of additional servers over IP
  • UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot
  • Built-in Emergency Power Off (EPO) interface with cable
  • Factory installed NEMA 5-20P input plug; user configurable L5-20P or L5-30P input plug-in connections supported
  • NEMA 5-15R, NEMA 5-15/20R and L5-20R output receptacles
  • Integrated 3 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (1 outlet per load bank)
  • Front panel LEDs offer current monitoring and battery charge level information
  • UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user required

Package Includes

  • SMART2600RM2U UPS System, PowerAlert Software and cabling, 4-post rackmount installation hardware, Instruction manual
OUTPUT  
Output Volt Amp Capacity (VA) 2600
Output kVA capacity (kVA) 2.6
Output Watt Capacity (watts) 2100
Output kW capacity 2.1
Output power factor 0.8
Nominal Output Voltage(s) Supported 120V
Frequency compatibility 60 Hz
Output voltage regulation (line mode) -18%, +8%
Output voltage regulation (Battery mode) +/- 5%
Built-in UPS output receptacles 4 5-15R outlet(s); 4 5-15/20R outlet(s); 1 L5-20R outlet(s)
Built-in controllable switched load banks Three switchable single-outlet 5-15R load banks
Output circuit breaker 15A breaker protects 5-15R, 20A breaker
protects 5-15/20R, L5-20R is unbreakered
Output AC waveform (AC mode) Sine wave
Output AC waveform (battery mode) Pure Sine wave
INPUT  
Rated input current (at maximum load) 24A (with user-supplied L5-30P plug),
16A (with factory 5-20P plug)
Nominal Input Voltage(s) Supported 120V AC
UPS input connection type 5-20P
Input circuit breaker 30A
UPS Input cord length (ft.) 10
UPS Input cord length (m) 3
Recommended Electrical Service 20A 120V
Phase Single-Phase
BATTERY  
Full load runtime (minutes) 4 min. (2100w)
Half load runtime (minutes) 11 min. (1050w)
Expandable battery runtime Extended runtime supported via optional external battery packs
External battery pack compatibility BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible);
BP48V27-2US (multi-pack compatible)
DC system voltage (VDC) 48
Battery recharge rate (included batteries) Less than 4.5 hours from 10% to 90%
Replacement battery cartridge
(internal UPS battery replacement)
RBC94-2U
Battery Access Front panel battery access door
Battery replacement description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION  
Voltage regulation description Automatic voltage regulation (AVR) maintains line power
operation with an input voltage range of 83 to 147
Overvoltage correction Input voltages between 127 and 147 are reduced by 12%
Undervoltage correction Input voltages between 95 and 104 are boosted by 12%
Severe undervoltage correction Input voltages between 83 and 94 are boosted by 24%
LEDS ALARMS & SWITCHES  
LED Indicators 5 LEDs indicate line power, battery power, overload,
voltage regulation and battery low/replace status
Alarms Audible alarm indicates power-failure,
overload and low-battery conditions
Alarm cancel operation Power-fail alarm can be silenced using alarm-cancel switch;
once silenced, alarm will re-sound to indicate low-battery status
Switches 2 Switches control off/on power status
and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION  
UPS AC suppression joule rating 480
UPS AC suppression response time Instantaneous
EMI / RFI AC noise suppression Yes
PHYSICAL  
Installation form factors supported
with optional accessories
2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary form factor Rackmount
UPS / Power Module dimensions
in primary form factor
(height x width x depth / inches)
3.5 x 17.5 x 19
UPS / Power Module dimensions
in primary form factor
(height x width x depth / cm)
8.9 x 44.4 x 48.3
Rack Height 2U
Secondary form factor Tower (requires 2-9USTAND)
UPS / Power Module weight (lbs) 64
UPS / Power Module weight (kg) 29.1
UPS Shipping dimensions
(height x width x depth / inches)
9 x 23.5 x 20
UPS Shipping dimensions
(height x width x depth / cm)
22.9 x 59.7 x 50.8
Shipping weight (lbs) 72
Shipping weight (kg) 32.7
Cooling method Fan
UPS housing material Steel
ENVIRONMENTAL  
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC mode BTU / hr. (full load) 297.5
Battery mode BTU / hr. (full load) 136000%
AC mode efficiency rating (100% load) 96%
COMMUNICATIONS  
Communications interface USB (HID enabled); DB9 Serial; Contact closure
Network monitoring port description Supports detailed monitoring of UPS and site power conditions;
1 USB port and 1 DB9 serial contact closure port
PowerAlert software Included
Communications cable USB and DB9 cabling included
WatchDog compatibility Supports Watchdog application, OS and
hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER  
Transfer time 5 milliseconds
Low voltage transfer to battery power (setpoint) 83
High voltage transfer to battery power (setpoint) 145
SPECIAL FEATURES  
Grounding lug Back panel grounding lug
Cold Start (startup in battery
mode during a power failure)
Cold-start operation supported
High availability UPS features Hot swappable batteries
Green & high efficiency features Greater than 95% efficiency - GREEN UPS;
Individually controllable load banks
CERTIFICATIONS  
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada);
Tested to NOM (Mexico); Meets FCC Part 15
Category A (EMI)
WARRANTY  
Product Warranty Period (Worldwide) 2-year warranty, 3 year with registration.
Note: Registration is required for 3-year warranty.
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
$250,000 Ultimate Lifetime Insurance

Specs Overview