Image may not exactly match the product.

Tripp Lite SU2200RTXLCD2U SmartOnline 2.2kVA Double-Conv UPS RM/TWR

SKU:
SU2200RTXLCD2U
Shipping:
$99.00 (Fixed Shipping Cost)
$2,791.16 $1,344.87
(You save $1,446.29 )

Image may not exactly match the product.

In-Stock

$2,791.16 $1,344.87
(You save $1,446.29 )
Availability:
In Stock. Ships Same Business Day If Ordered Before 3pm PT

Condition:
New
Warranty Information
2 Years

Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.

Share:

2.2kVA On-Line Double-Conversion UPS, 2U Rack/Tower, Interactive LCD display

 

 

Key Features

  • Tripp Lite SU2200RTXLCD2U 2200VA / 2.2kVA / 1800W on-line, double-conversion 2U rack / tower UPS
  • Selectable 100/110/120/127V output (120V factory preset)
  • NEMA 5-20P input, 6 NEMA 5-15/20R and 1 L5-20R outlets
  • Two switched 3-outlet load banks support remote reboot or programmable load shedding options
  • Supports 2% output voltage regulation and zero transfer time in double conversion mode
  • Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions
  • 12 minutes runtime at 50% load (900W) and 4 minutes at 100% load (1800W) with internal batteries
  • BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs available (some configurations require Tripp Lite External Battery Configuration Software)
  • LCD interface reports operating mode plus 9 selectable screens of UPS data (Load % & kW, Load % & kVA, Power factor, Input volts & Hz, Output volts & Hz, Battery volts and charge %, Minutes runtime, Capacity remaining, Kw/hr. consumption)
  • LCD interface also supports 16 screens of UPS configuration and setup options
  • 4 post installation hardware included, Optional 2POSTRMKITHD enables 2 post rack installation, Optional 2-9USTAND enables tower placement
  • Single line TEL / Network surge suppression
  • Electronic bypass maintains utility output during a variety of UPS fault conditions
  • Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
  • Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz
  • USB, RS-232, contact-closure and optional SNMPWEBCARD accessory monitoring options
  • HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
  • Included PowerAlert UPS monitoring software

Package Includes

  • SU2200RTXLCD2U UPS System
  • PowerAlert Software with USB, Serial & EPO cabling
  • 4 post rackmount installation kit
  • Instruction manual
OUTPUT  
Output Volt Amp Capacity (VA) 2200
Output kVA capacity (kVA) 2.2
Output Watt Capacity (watts) 1800
Output kW capacity 1.8
Output power factor 19:40
Output Capacity Details ON LINE MODE: Maximum output capacity ratings
are reduced for some nominal voltage settings (127/120V
1800 watts / 115V 1620 watts / 110V 1530 watts / 100V
1440 watts). FREQUENCY REGULATION / CONVERSION
MODE: Maximum output ratings are reduced in frequency
regulation / conversion mode (127/120V 1260 watts / 115V
1134 watts / 110V 1071 watts / 100V 1008 watts)
Crest Factor 3:01
Nominal Output Voltage(s) Supported 100V; 110V; 115V; 120V; 127V
Nominal Voltage details 120V factory-default nominal voltage
Frequency compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency compatibility details ON LINE MODE: Output frequency is automatically
configured to match nominal input frequency on startup;
Output matches input frequency when +/-5Hz of nominal;
Output is regulated to +/-0.05Hz when input frequency
exceeds +/-5Hz of nominal. UPS switches to battery
mode when input frequency is below 40Hz or above 70Hz.
FREQUENCY REGULATION / CONVERSION MODE:
Output is regulated to +/-0.05Hz of selected output frequency
input is 40 to 70Hz; UPS switches to battery mode when input
frequency is below 40Hz or above 70Hz. BATTERY MODE:
Output is regulated to +/-0.05Hz.
Output voltage regulation (line mode) +/- 2%
Output voltage regulation (Economy line mode) +/- 10%
Output voltage regulation (Battery mode) +/- 3%
Built-in UPS output receptacles 6 5-15/20R outlet(s); 1 L5-20R outlet(s)
Built-in controllable switched load banks Two switchable three-outlet 5-15/20R load banks
Output AC waveform (AC mode) Pure Sine wave
Output AC waveform (battery mode) Pure Sine wave
INPUT  
Rated input current (at maximum load) 16A
Nominal Input Voltage(s) Supported 100V AC; 110V AC; 115V AC; 120V AC; 127V AC
Nominal input voltage description 120V factory default
UPS input connection type 5-20P
Input circuit breaker 30A
UPS Input cord length (ft.) 10
UPS Input cord length (m) 3
Recommended Electrical Service 20A 120V
Phase Single-Phase
BATTERY  
Full load runtime (minutes) 4 min. (1800w)
Half load runtime (minutes) 12 min. (900w)
Expandable battery runtime Extended runtime supported via optional external battery packs
External battery pack compatibility BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible);
BP48V27-2US (multi-pack compatible)
Expandable runtime description Some external battery configurations require the use of Tripp Lite's
External Battery Configuration Software, see manual for details
DC system voltage (VDC) 48
Battery recharge rate (included batteries) Less than 3 hours recharge to 90%
Replacement battery cartridge
(internal UPS battery replacement)
RBC94-2U
Battery Access Front panel battery access
Battery replacement description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION  
Voltage regulation description Online, double-conversion power conditioning maintains 2%
output voltage regulation during brownouts and overvoltages
Overvoltage correction Corrects overvoltages to 150V (0-100% load)
Undervoltage correction Corrects undervoltages to 100V at full load (90V at 100V nominal)
Severe undervoltage correction Corrects brownouts to 70V (70% load) & 55V (33% load)
LEDS ALARMS & SWITCHES  
LED Indicators 7 front panel LEDs indicate line power availability, AC to DC
conversion, battery mode operation, inverter mode, eco mode
operation, bypass mode operation and AC output status
Front panel LCD display Front panel LCD information and configuration screen offers
detailed UPS and site power status and operating data, plus
configuration of voltage, frequency, operating mode, alarm
function and a variety of additional options
Alarms Audible alarm indicates UPS startup, power-failure, low-battery,
overload, UPS fault and remote shutdown conditions
Alarm cancel operation Power-fail alarm can be temporarily silenced using alarm-cancel
switch; silent mode alarm configuration option available
Switches 2 switches control off/on power status and alarm-cancel operation;
2 additional scroll-down and scroll-up / select options enable LCD
status viewing and configuration options
SURGE / NOISE SUPPRESSION  
UPS AC suppression joule rating 570
UPS AC suppression response time Instantaneous
UPS Dataline suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
EMI / RFI AC noise suppression Yes
PHYSICAL  
Installation form factors supported
with included accessories
4 post 19 inch rackmount
Installation form factors supported
with optional accessories
2 post rackmount (2POSTRMKITWM);
2 post rackmount (2POSTRMKITHD);
Wallmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary form factor Rackmount
UPS / Power Module dimensions
in primary form factor
(height x width x depth / inches)
3.5 x 17.5 x 19
UPS / Power Module dimensions
in primary form factor
(height x width x depth / cm)
8.9 x 44.4 x 48.3
Rack Height 2U
Secondary form factor Tower (requires 2-9USTAND)
UPS / Power Module weight (lbs) 48.5
UPS / Power Module weight (kg) 2200%
UPS Shipping dimensions
(height x width x depth / inches)
9.5 x 20 x 24
UPS Shipping dimensions
(height x width x depth / cm)
24.1 x 50.8 x 61
Shipping weight (lbs) 61.5
Shipping weight (kg) 27.9
Cooling method Fan
UPS housing material Steel
ENVIRONMENTAL  
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC mode BTU / hr. (full load) 68300%
AC economy mode BTU / hr. (full load) 39000%
Battery mode BTU / hr. (full load) 83800%
AC economy mode efficiency rating (100% load) 94%
Operating Elevation (ft.) 0-3000m / 0-10,000 ft.
Audible Noise 57 dBA at 1m front side
Operating Elevation (m) 0-3000 m
COMMUNICATIONS  
Communications interface USB (HID enabled); DB9 Serial; Contact closure;
EPO (emergency power off); Slot for SNMP/Web interface
Network monitoring port description Supports detailed monitoring of UPS and site power conditions;
DB9 port supports RS232 and contact closure communications
PowerAlert software Included
Communications cable USB and DB9 cabling included
WatchDog compatibility Supports Watchdog application, OS and
hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER  
Transfer time Zero (0 milliseconds) in double-conversion mode;
4 milliseconds economy mode
Low voltage transfer to battery power (setpoint) 100V at full load (90V full load at 100V nominal setting);
70V at 70% load; 55V at 33% load
High voltage transfer to battery power (setpoint) 150
SPECIAL FEATURES  
Cold Start (startup in battery
mode during a power failure)
Cold-start operation supported
High availability UPS features Automatic inverter bypass; Hot swappable batteries
Green & high efficiency features High efficiency economy mode operation; Individually
controllable load banks; Schedulable daily hours of
economy mode operation
CERTIFICATIONS  
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada);
Meets FCC Part 15 Category A (EMI);
ROHS (Restriction of Hazardous Substances);
ENERGY STAR Qualified
WARRANTY  
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
$250,000 Ultimate Lifetime Insurance

Specs Overview

Detailed Specs