Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.
Share:
6000VA UPS Smart Online High Efficiency 6U RM 6kVA 208-240V
This product is very heavy and normally ships on a pallet. Specific arrangements must be made with Hummingbird Networks to arrange delivery after order is submitted.
Key Features
- Tripp Lite SU6000RT4UTF 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a 6U rack/tower compatible configuration (4U power module plus 2U low-voltage transformer; at 208V nominal, output is limited to 4992 watts)
- Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
- Detachable back panel PDU contains input line cord connection, output receptacles and manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment
- L6-30P input plug
- UPS supported outlets include two L6-30R, two L6-20R, 8 5-15/20R and 4 5-15R outlets
- Included rail kit supports 4U 19 inch rackmount installation in 4 post racks
- Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (2 required for SU6000RT4UTF)
- Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UTF)
- Maximum installed rack depth of only 21.8 in. / 55.3 cm
- Maintains full-time sine wave output within 2% of selected 208/240V and 120V nominal at 60Hz in double conversion mode
- Corrects brownouts to 156V at full load (100V at 50% load or less)
- Corrects overvoltages to 290V at full load (300V at 90% load or less)
- Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
- High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs
- Network-grade AC surge and noise suppression
- Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces
- UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part # RELAYIOCARD)
- Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces
- Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification
- Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)
- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices
- Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations
- LED/LCD display panel rotates for viewing in rackmount or tower configurations
- Supports Emergency Power Off (EPO) via built-in interface
- Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
- BP192V12-3U external battery packs are field replaceable and hot swappable
- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- $250,000 connected equipment insurance;
OUTPUT | |
Output Volt Amp Capacity (VA) | 6000 |
Output kVA capacity (kVA) | 6 |
Output Watt Capacity (watts) | 5400 |
Output kW capacity | 5.4 |
Output power factor | 21:36 |
Output Capacity Details | Output capacity de-rates to 4992 watts when used at 208V nominal |
Crest Factor | 3:01 |
Nominal Output Voltage(s) Supported | 120V; 208V; 240V |
Frequency compatibility | 60 Hz |
Frequency compatibility details | Output frequency regulation +/-0.05Hz (free running) |
Output voltage regulation (line mode) | +/- 2% |
Output voltage regulation (Economy line mode) | +/- 10% |
Output voltage regulation (Battery mode) | +/- 2% |
Built-in UPS output receptacles | 4 5-15R outlet(s); 8 5-15/20R outlet(s); 2 L6-20R outlet(s); 2 L6-30R outlet(s) |
Output receptacle details | Output receptacles and input line cord are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement |
Output circuit breaker | High voltage 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered; Low voltage 20A breakers protect 4 5-15/20R outlets each; Low voltage 15A breakers protect 2 5-15/20R outlets each |
Output AC waveform (AC mode) | Pure Sine wave |
Output AC waveform (battery mode) | Pure Sine wave |
INPUT | |
Rated input current (at maximum load) | 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V) |
Nominal Input Voltage(s) Supported | 208V AC; 240V AC |
Nominal input voltage description | Factory configured to 208V |
UPS input connection type | L6-30P |
UPS Input cord length (ft.) | 10 |
UPS Input cord length (m) | 3 |
Recommended Electrical Service | 30A |
Phase | Single-Phase |
BATTERY | |
Full load runtime (minutes) | 2 min. (5400 watts) |
Half load runtime (minutes) | 8.5 min. (2700 watts) |
Expandable battery runtime | Runtime is expandable with external battery packs |
External battery pack compatibility | BP192V12-3U; BP192V557C-1PH; BP192V787C-1PH; BP192V1037C-1PH; BP192V1407C-1PH |
DC system voltage (VDC) | 192 |
Battery recharge rate (included batteries) | 6 hours from 10% to 90% (internal batteries) |
Replacement battery cartridge (internal UPS battery replacement) | RBC5-192 |
Battery Access | Front panel battery access door |
Battery replacement description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
Voltage regulation description | Online, double-conversion power conditioning |
Overvoltage correction | Corrects overvoltages as high as 300V (<90% load) and 280V (full load) |
Undervoltage correction | Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly |
LEDS ALARMS & SWITCHES | |
LED Indicators | 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options |
Alarms | Unique audible alarms for all major UPS, environmental and power conditions (see manual) |
Alarm cancel operation | Alarm cancel switch |
Switches | Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads. |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression response time | Instantaneous |
EMI / RFI AC noise suppression | Yes |
PHYSICAL | |
Installation form factors supported with included accessories | 4 post 19 inch rackmount |
Included mounting accessory description | Two sets of adjustable 4 post 19 inch rackmount installation rails included |
Installation form factors supported with optional accessories | 2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND) |
Optional mounting accessory notes | 2 post rackmount installation requires TWO 2POSTRMKITHD accessories, Tower installation requires ONE 2-9USTAND accessory. |
Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 6.85 x 17.5 x 20.7 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 17.4 x 44.5 x 52.6 |
Installed whole system maximum rack depth (inches) | 2180% |
Installed whole system maximum rack depth (cm) | 55.4 |
Rack Height | 6U |
Secondary form factor | Tower |
UPS / Power Module weight (lbs) | 116.2 |
UPS / Power Module weight (kg) | 5280% |
Stepdown transformer dimensions (height x width x depth / inches) | 3.5 x 17.5 x 21.8 |
Stepdown transformer dimensions (height x width x depth / cm) | 8.8 x 44.5 x 55.4 |
Stepdown transformer weight (lbs) | 7260% |
Stepdown transformer weight (kg) | 3300% |
UPS Shipping dimensions (height x width x depth / inches) | 22.5 x 25 x 30 |
UPS Shipping dimensions (height x width x depth / cm) | 57.2 x 63.5 x 76.2 |
Shipping weight (lbs) | 293 |
Shipping weight (kg) | 13300% |
Cooling method | Fans |
UPS housing material | Steel |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 176700% |
AC economy mode BTU / hr. (full load) | 70700% |
Battery mode BTU / hr. (full load) | 178400% |
AC mode efficiency rating (100% load) | 90% |
AC economy mode efficiency rating (100% load) | 96% |
Operating Elevation (ft.) | 0-3000m (0 to 10,000 ft.) |
Audible Noise | 60 dBA at front side 1 meter |
Operating Elevation (m) | 0-3000 m |
COMMUNICATIONS | |
Communications interface | USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
Network monitoring port description | Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports |
PowerAlert software | Included |
Communications cable | USB, DB9 serial and EPO cables included |
WatchDog compatibility | Yes |
LINE / BATTERY TRANSFER | |
Transfer time | No transfer time (0 ms.) in online, double-conversion mode |
Low voltage transfer to battery power (setpoint) | 156V (full load) / 100V (50% load or less, derates linearly) |
High voltage transfer to battery power (setpoint) | 280V (full load) / 300V (90% load or less) |
SPECIAL FEATURES | |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
High availability UPS features | Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module; Hot swappable batteries |
Green & high efficiency features | High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances) |
UPS Certification details | IEC 61000-4-5 1995 B Surge Immunity |
WARRANTY | |
Product Warranty Period (Worldwide) | 2-year limited warranty |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |