OUTPUT | |
Output Volt Amp Capacity (VA) | 1500 |
Output kVA capacity (kVA) | 1.5 |
Output Watt Capacity (watts) | 900 |
Nominal Output Voltage(s) Supported | 115V; 120V |
Frequency compatibility | 60 Hz |
Output voltage regulation (line mode) | -18%, +8% |
Output voltage regulation (Battery mode) | 115V (+/- 5%) |
Built-in UPS output receptacles | 8 5-15R outlet(s) |
Output AC waveform (AC mode) | Sine wave |
Output AC waveform (battery mode) | PWM sine wave |
INPUT | |
Rated input current (at maximum load) | 8.5A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS input connection type | 5-15P |
Input circuit breaker | 10A |
UPS Input cord length (ft.) | 6 |
UPS Input cord length (m) | 1.8 |
Recommended Electrical Service | 15A 120V |
Phase | Single-Phase |
BATTERY | |
Full load runtime (minutes) | 3.5 min. (900w) |
Half load runtime (minutes) | 13 min. (450w) |
DC system voltage (VDC) | 24 |
Battery recharge rate (included batteries) | Less than 4.5 hours from 10% to 90% |
VOLTAGE REGULATION | |
Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
Overvoltage correction | Input voltages between 128 and 147 are reduced by 12% |
Undervoltage correction | Input voltages between 93 and 107 are boosted by 14% |
Severe undervoltage correction | Input voltages between 75 and 92 are boosted by 30% |
LEDS ALARMS & SWITCHES | |
LED Indicators | Front panel LCD display |
Front panel LCD display | Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace battery status; LCD screen rotates for rack/tower viewing |
Alarms | Audible alarm indicates power-failure and low-battery conditions |
Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation; dimmer switch controls LCD brightness |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression joule rating | 480 |
UPS AC suppression response time | Instantaneous |
UPS Dataline suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
EMI / RFI AC noise suppression | Yes |
PHYSICAL | |
Installation form factors supported with included accessories | Tower |
Included mounting accessory description | Pair of mounting ears enable tower and 2-4 post rackmount installation |
Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 3.5 x 17.3 x 10.5 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 8.9 x 43.8 x 26.7 |
Installed whole system dimensions in secondary form factor (height x width x depth / cm) | 43.8 x 8.9 x 26.7 |
Installed whole system maximum rack depth (inches) | 10.5 |
Installed whole system maximum rack depth (cm) | 26.7 |
Rack Height | 2U |
Secondary form factor | Tower |
Installed whole system dimensions in secondary form factor (height x width x depth / inches) | 17.3 x 3.5 x 10.5 |
UPS dimensions in secondary form factor (height x width x depth / cm) | 43.8 x 8.9 x 26.7 |
UPS / Power Module weight (lbs) | 29.4 |
UPS / Power Module weight (kg) | 13.3 |
UPS Shipping dimensions (height x width x depth / inches) | 7.5 x 15 x 21.5 |
UPS Shipping dimensions (height x width x depth / cm) | 19 x 38.1 x 54.6 |
Shipping weight (lbs) | 33.4 |
Shipping weight (kg) | 15.2 |
Cooling method | Fan |
UPS housing material | ABS |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 255 |
AC mode efficiency rating (100% load) | 92% |
COMMUNICATIONS | |
Communications interface | USB (HID enabled); DB9 Serial |
Network monitoring port description | Supports detailed monitoring of UPS and site power conditions |
PowerAlert software | Free download from www.tripplite.com |
Communications cable | USB and DB9 Serial cabling included |
WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER | |
Transfer time | 4 milliseconds |
Low voltage transfer to battery power (setpoint) | 75 |
High voltage transfer to battery power (setpoint) | 147 |
SPECIAL FEATURES | |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI) |
WARRANTY | |
Product Warranty Period (U.S. & Canada) | 3-year limited warranty |
Product Warranty Period (Latin America) | 3-year limited warranty |
Product Warranty Period (International) | 2-year limited warranty |
Product Warranty Period (Mexico) | 3-year limited warranty |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |