Tripp Lite PDU ATS/Metered 3.8kW 200-240V Single-Phase - 8 C13 and 2 C19 Outlets, Dual C20 Inlets, 12 Ft. Cords, 1U, TAA - Power Distribution Unit - 3.84 KW - TAA Compliant - PDUMH20HVATS

SKU:
PDUMH20HVATS
Shipping:
Calculated at Checkout
$638.36 $366.12
(You save $272.24 )

Image may not exactly match the product.

Out of Stock.

Request a quote for re-stock information.

$638.36 $366.12
(You save $272.24 )
Availability:
Currently out of stock, pre-order may be available

Condition:
New
Warranty Information
Limited Warranty - 2 years
Product Line:
Tripp Lite
Product Type:
Power distribution unit
Installation Type:
Rack-mountable
Model:
PDU ATS/Metered 3.8kW 200-240V Single-Phase - 8 C13 and 2 C19 Outlets, Dual C20 Inlets, 12 ft. Cords, 1U, TAA
Input Voltage:
AC 200/208/220/230/240 V
Power Provided:
3.84 kW

Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.

Share:
  • 8 C13 and 2 C19 200-240V outlets distribute AC power to connected equipment
  • Switches from primary to secondary power source in <5 ms for constant operation
  • Digital ammeter for on-site real-time load monitoring helps prevent power overloads
  • Dual 12 ft. power cables connect to separate primary and secondary power sources
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
  • This product is covered by a 2-year limited warranty

Single-Phase 20A ATS PDU Distributes and Monitors Network-Grade Power in Real Time
This metered PDU provides real-time local reporting of the total load level via its built-in digital current meter. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH20HVATS features eight C13 and two C19 200-240V outlets for connecting equipment. Outlets are factory-programmed for sequential turn-on at 250-millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction at startup.
Switches from Primary to Secondary Power Source in Milliseconds
Dual 12-foot (3.7-meter) power cables with C20 inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources. Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.
Digital Load Meter Helps Prevent Potentially Expensive Overloads
A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.
Mounts into 1U of Rack Space
Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack.
TAA-Compliant for GSA Schedule Purchases
The PDUMH20HVATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.