Warranty Information
2 Year
Product Type:
PDU
Input Voltage:
230 V AC
Output Voltage:
200 V AC,220 V AC,230 V AC
PDU Type:
Monitored
Phase:
Single Phase
Plug/Connector Type:
IEC-309 32A BLUE (2P+E)
Power Rating (Watt):
7400 W
Protection Type:
Overload Protection
Rack Height:
2U
Receptacle Type:
IEC 60320 C13,IEC 60320 C19
View More

Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.

Hear What Our Customers Are Saying

What Sets Us Apart

Real Humans. Real Help.

Forget chasing down reps or emailing into the abyss. Get your own IT Concierge — a real human who stays with you from start to finish. One point of contact. Zero runaround.

Rapid-Fire Quotes, No Fluff

Under the gun? We turn around Cisco & Meraki quotes in record time — even complex builds. No waiting days for basic pricing.

👉 Get My Fast Quote

Free Solution Design with White Glove Engineers

Need to validate your BoM or double-check your plan? Our Cisco-certified engineers review it with you, optimize where needed, and catch gotchas before they cost you…all free.

We Don’t Just Sell Boxes. We Build Solutions.

Pre-config, licensing help, and install guidance — we make sure what you buy solves your problem, the first time.

Trade-In Credits Without the Headaches

Turn your old gear into instant quote credits. We can coordinate the recycling or destruction in an environmentally friendly and safe manner. Enjoy a smoother path to your upgrade with built-in savings.

Unlock Pricing Other Buyers Don't See

Get access to exclusive Cisco/Meraki incentives, special pricing tiers, and project-based discounts you won’t find anywhere else.

Want to skip the back and forth? Talk directly to a specialist and get expert guidance in under 30 minutes.

ATS PDU allows real-time current metering and remote power monitoring to help prevent circuit overloads and ensure proper load balance.

Features Single-Phase 32A 200-240V ATS PDU Distributes and Monitors Network-Grade Power in Real Time

This monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via its built-in network interface. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMNH32HVAT2 features 16 C13 and 2 C19 outlets in two load banks, each bank protected by a 20A circuit breaker. Dual three-meter power cords with IEC 309 32A Blue inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.

Switches from Primary to Secondary Power Source in Milliseconds

Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 1-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.

Built-In LX Platform Network Management Card Allows Remote Access 24/7

The Java-free HTML5-based WEBCARDLX network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. The latest version of PowerAlert Device Manager (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite's PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.

Digital Load Meter Helps Prevent Potentially Expensive Overloads

A digital ammeter reports the total load for all connected equipment in amps and kilowatts. Monitoring capacity helps ensure load levels remain well below maximum capacity levels with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low. Current monitoring provides 1% billing grade accuracy

Mounts into 2U of Rack Space or on a Wall

Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.

TAA-Compliant for GSA Schedule Purchases

The PDUMNH32HVAT2 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
  • Availability: Currently out of stock, pre-order may be available
  • Condition: New
  • Warranty Information 2 Year
  • Product Type: PDU
  • Input Voltage: 230 V AC
  • Output Voltage: 200 V AC,220 V AC,230 V AC
  • PDU Type: Monitored
  • Phase: Single Phase
  • Plug/Connector Type: IEC-309 32A BLUE (2P+E)
  • Power Rating (Watt): 7400 W
  • Protection Type: Overload Protection
  • Rack Height: 2U
  • Receptacle Type: IEC 60320 C13,IEC 60320 C19