1500VA UPS Smart Pro RM/Tower Extended Run Line-Interactive 8 outlets

 

 

Key Features

  • Tripp Lite SMART1500RMXL2UA line interactive 2U rack/tower UPS with 1500VA / 1.5kVA / 1350W capacity and extended runtime options
  • Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V
  • NEMA 5-15P input plug; 8 NEMA 5-15R output receptacles, Two independently switched output load banks
  • Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages
  • High 95% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions
  • Internal batteries offer 14 minutes at 50% load (675W) and 4.9 minutes at 100% load (1350W)
  • Extended runtime is available with optional BP36V15-2U (limit 1); BP36V42-3U (multi-pack compatible); BP36V27-2US (multi-pack compatible), Output is reduced to 1200 watts maximum with external battery packs
  • External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
  • Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment
  • Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information
  • LCD interface also supports a number of advanced user setup and operating preferences
  • Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement
  • Built-in USB, RS-232 and optional SNMPWEBCARD accessory monitoring options
  • HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
  • Included PowerAlert UPS monitoring software; Built-in Emergency Power Off (EPO) interface with cable

Package Includes

  • SMART1500RMXL2UA UPS system
  • PowerAlert software with USB, Serial & EPO cabling
  • 4 post installation kit
  • Owner's manual
OUTPUT  
Output Volt Amp Capacity (VA) 1500
Output kVA capacity (kVA) 1.5
Output Watt Capacity (watts) 1350
Output kW capacity 8:24
Output power factor 0.9
Output Capacity Details Output derates to 1200 watts in all external battery configurations
Nominal Output Voltage(s) Supported 120V
Frequency compatibility 60 Hz
Output voltage regulation (line mode) -14%, +6%
Output voltage regulation (Battery mode) +/- 5%
Built-in UPS output receptacles 8 5-15R outlet(s)
Built-in controllable switched load banks Two switchable two-outlet 5-15R load banks
Output AC waveform (AC mode) Sine wave
Output AC waveform (battery mode) Pure Sine wave
INPUT  
Rated input current (at maximum load) 12A
Nominal Input Voltage(s) Supported 120V AC
UPS input connection type 5-15P
Input circuit breaker 15A
UPS Input cord length (ft.) 10
UPS Input cord length (m) 3
Recommended Electrical Service 15A 120V
Phase Single-Phase
BATTERY  
Full load runtime (minutes) 4.9 min. (1350w)
Half load runtime (minutes) 14 min. (675w)
Expandable battery runtime Extended runtime supported via optional external battery packs
External battery pack compatibility BP36V15-2U (limit 1); BP36V42-3U (multi-pack compatible);
BP36V27-2US (multi-pack compatible)
DC system voltage (VDC) 36
Battery recharge rate (included batteries) Less than 4.5 hours from 10% to 90%
Replacement battery cartridge
(internal UPS battery replacement)
RBC93-2U
Battery Access Front panel battery access door
Battery replacement description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION  
Voltage regulation description Automatic voltage regulation (AVR) maintains line power
operation with an input voltage range of 83 to 145
Overvoltage correction Input voltages between 127 and 145 are reduced by 12%
Undervoltage correction Input voltages between 95 and 108 are boosted by 12%
Severe undervoltage correction Input voltages between 83 and 94 are boosted by 24%
LEDS ALARMS & SWITCHES  
Front panel LCD display Front panel LCD information and configuration screen offers
detailed UPS and site power status and operating data, plus
configuration of voltage, operating mode, alarm function and
a variety of additional options (see manual for detailed LCD
configuration and monitoring options)
Alarms Audible alarm indicates UPS startup,
power-failure, low-battery, overload,
UPS fault and remote shutdown conditions
Alarm cancel operation Power-fail alarm can be temporarily silenced using
alarm-cancel switch; silent mode alarm configuration
option available
Switches 3 pushbutton switches control OFF / ON power status,
MODE selection and MUTE / ENTER control functions
SURGE / NOISE SUPPRESSION  
UPS AC suppression joule rating 570
UPS AC suppression response time Instantaneous
EMI / RFI AC noise suppression Yes
PHYSICAL  
Installation form factors supported
with included accessories
4 post 19 inch rackmount
Included mounting accessory description Adjustable mounting rail kit included
Installation form factors supported
with optional accessories
2 post rackmount (2POSTRMKITWM);
Wallmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary form factor Rackmount
UPS / Power Module dimensions
in primary form factor
(height x width x depth / inches)
3.45 x 17.3 x 13.45
UPS / Power Module dimensions
in primary form factor
(height x width x depth / cm)
8.8 x 43.9 x 34.2
Rack Height 2U
Secondary form factor Tower (requires 2-9USTAND)
UPS / Power Module weight (lbs) 46.5
UPS / Power Module weight (kg) 21.1
UPS Shipping dimensions
(height x width x depth / inches)
8.5 x 23.4 x 19.9
UPS Shipping dimensions
(height x width x depth / cm)
21.6 x 59.4 x 50.5
Shipping weight (lbs) 51.3
Shipping weight (kg) 23.3
Cooling method Fan
UPS housing material Steel
ENVIRONMENTAL  
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC mode BTU / hr. (full load) 237
AC mode efficiency rating (100% load) 95%
COMMUNICATIONS  
Communications interface USB; DB9 Serial; EPO (emergency power off);
Slot for SNMP/Web interface
Network monitoring port description Supports detailed monitoring of UPS and site power conditions
PowerAlert software Included
Communications cable USB and DB9 cabling included
WatchDog compatibility Supports Watchdog application, OS and hard-reboot
restart options for remote applications
LINE / BATTERY TRANSFER  
Transfer time 4 milliseconds (AC to battery mode),
1 millisecond (Battery to AC mode)
Low voltage transfer to battery power (setpoint) 83
High voltage transfer to battery power (setpoint) 145
SPECIAL FEATURES  
Grounding lug Back panel grounding lug
Cold Start (startup in battery
mode during a power failure)
Cold-start operation supported
High availability UPS features Hot swappable batteries
Green & high efficiency features Greater than 95% efficiency - GREEN UPS;
Individually controllable load banks
CERTIFICATIONS  
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada);
Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI);
ROHS (Restriction of Hazardous Substances)
WARRANTY  
Product Warranty Period (Worldwide) 2-year warranty, 3 year with registration.
Note: Registration is required for 3-year warranty.
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
$250,000 Ultimate Lifetime Insurance

Specs Overview