ADTRAN NetVanta 1700 Series Switches

Build high-performance aggregation, access, campus, and enterprise networks with ADTRAN NetVanta 1700 Series switches from Hummingbird Networks. The NetVanta 1700 family includes high-bandwidth managed Ethernet switching designed for organizations that need multigigabit connectivity, 10 Gigabit fiber, 25 Gigabit uplinks, Layer 2 and Layer 3 networking, advanced redundancy, and scalable enterprise network management.

The current ADTRAN NetVanta 1700 Series is centered on the NetVanta 1760 family, including the NetVanta 1760-8F and NetVanta 1760-12F. These managed switches are designed for bandwidth-intensive enterprise applications, fiber aggregation, high-speed switch uplinks, server connectivity, campus networks, distributed business environments, and other applications where conventional Gigabit access switching no longer provides sufficient capacity.

Choosing the correct NetVanta 1700 Series switch depends on required 10G port density, 25G uplink requirements, copper versus fiber connectivity, Layer 3 routing, redundancy, switching capacity, network topology, and expected future bandwidth growth.

ADTRAN NetVanta 1700 Series Switches

ADTRAN NetVanta 1700 Series switches provide managed high-speed Ethernet connectivity for organizations moving beyond conventional Gigabit access switching.

Current NetVanta 1700 Series switching includes:

  • ADTRAN NetVanta 1760-8F
  • ADTRAN NetVanta 1760-12F

The NetVanta 1760 family is designed around multigigabit fiber aggregation and high-bandwidth enterprise access.

ADTRAN NetVanta 1760 Series

The ADTRAN NetVanta 1760 Series consists of fully managed Layer 2 and Layer 3 switches designed for bandwidth-intensive business and enterprise networking.

The family provides:

  • 10 Gigabit SFP+ connectivity
  • 10 Gigabit RJ45 connectivity on the 1760-8F
  • 25 Gigabit SFP28 uplinks on the 1760-12F
  • Layer 2 switching
  • Layer 3 routing
  • VLANs
  • Quality of Service
  • Link aggregation
  • Enterprise security features
  • Advanced network management
  • Redundancy features

ADTRAN NetVanta 1760-8F

The NetVanta 1760-8F is a compact multigigabit managed switch designed for high-speed aggregation and access applications.

It provides:

  • 8 multi-rate SFP+ ports
  • 2 multi-rate RJ45 Ethernet ports
  • Up to 10 Gigabit Ethernet connectivity
  • Layer 2 and Layer 3 switching
  • Managed enterprise networking
  • Up to 200 Gbps switching performance

The 1760-8F can be a strong fit for environments requiring a mix of high-speed optical and copper Ethernet interfaces without the port density of a larger aggregation switch.

NetVanta 1760-8F SFP+ Ports

The eight SFP+ ports on the NetVanta 1760-8F are multi-rate interfaces.

Supported rates include:

  • 100 Mbps
  • 1 Gigabit
  • 2.5 Gigabit
  • 5 Gigabit
  • 10 Gigabit

This flexibility allows the switch to integrate into networks containing multiple generations of optical infrastructure.

NetVanta 1760-8F 10G RJ45 Ports

The NetVanta 1760-8F also provides two multi-rate RJ45 Ethernet ports.

These copper interfaces support speeds up to 10 Gigabit Ethernet and can be useful for:

  • Servers
  • Network appliances
  • Other switches
  • High-performance workstations
  • 10GBASE-T infrastructure

ADTRAN NetVanta 1760-12F

The NetVanta 1760-12F is the higher-capacity model in the current NetVanta 1760 Series.

It provides:

  • 12 multi-rate SFP+ ports
  • 2 multi-rate SFP28 ports
  • 10 Gigabit Ethernet connectivity
  • 25 Gigabit Ethernet uplinks
  • Layer 2 and Layer 3 switching
  • Up to 340 Gbps switching performance
  • Optional redundant hot-swappable power

The 1760-12F is well suited to aggregation, high-speed campus networking, fiber-heavy enterprise infrastructure, and environments where 25 Gigabit uplink capacity is required.

NetVanta 1760-12F SFP+ Ports

The NetVanta 1760-12F includes twelve multi-rate SFP+ ports.

These interfaces support multiple Ethernet speeds up to 10 Gigabit, allowing organizations to connect compatible:

  • Access switches
  • Servers
  • Fiber uplinks
  • Storage systems
  • Network appliances
  • Other aggregation infrastructure

NetVanta 1760-12F SFP28 Ports

The two SFP28 interfaces on the NetVanta 1760-12F support Ethernet speeds up to 25 Gigabit.

SFP28 connectivity can provide high-bandwidth uplinks between:

  • Aggregation and core switches
  • High-performance network layers
  • Servers
  • Data-center infrastructure
  • Campus distribution switches

ADTRAN 25 Gigabit Switching

25 Gigabit Ethernet provides significantly more uplink capacity than 10 Gigabit Ethernet while retaining the compact SFP form factor through SFP28.

The NetVanta 1760-12F can use 25G connectivity for high-bandwidth aggregation and uplinks.

ADTRAN 10 Gigabit Switches

Both current NetVanta 1760 models provide extensive 10 Gigabit connectivity.

10G Ethernet can support:

  • Switch-to-switch uplinks
  • Enterprise aggregation
  • Server connectivity
  • Storage traffic
  • Campus fiber backbones
  • High-bandwidth network appliances

ADTRAN Multigigabit Switches

The NetVanta 1760 family uses multi-rate ports that can operate at several Ethernet speeds rather than requiring every link to operate at 10G or 25G.

This can simplify migration from existing network infrastructure because compatible links can operate at:

  • 100 Mbps
  • 1 Gigabit
  • 2.5 Gigabit
  • 5 Gigabit
  • 10 Gigabit
  • 25 Gigabit on compatible 1760-12F SFP28 ports

ADTRAN Fiber Aggregation Switches

The NetVanta 1760 Series is particularly well suited to fiber aggregation.

Fiber aggregation switches consolidate traffic from multiple network segments and forward it through higher-bandwidth uplinks toward core infrastructure.

Applications can include:

  • Campus distribution
  • Building aggregation
  • Enterprise network cores
  • Server rooms
  • Fiber access networks
  • Multi-building facilities

What Is an Aggregation Switch?

An aggregation switch sits between access-layer switches and higher-level core or routing infrastructure.

Its role is to consolidate traffic from multiple network segments while providing sufficient uplink bandwidth to avoid bottlenecks.

ADTRAN Access vs. Aggregation Switching

Access switch: Connects endpoint devices such as computers, phones, cameras, and wireless access points.

Aggregation switch: Combines traffic from multiple access switches and forwards it toward higher-capacity network infrastructure.

The NetVanta 1760 family can perform aggregation or high-bandwidth access roles depending on network design.

Layer 3 ADTRAN NetVanta 1700 Switches

NetVanta 1760 switches support non-blocking Layer 2 and Layer 3 networking.

Layer 3 capabilities include support for:

  • Static routing
  • RIP
  • OSPF
  • IPv4 routing
  • IPv6 routing
  • DHCP functionality
  • Routing between VLANs

Static Routing

Static routing allows administrators to manually define network paths between connected networks.

This can be useful in predictable enterprise environments where routing topology changes infrequently.

OSPF Support

The NetVanta 1760 Series supports OSPF for dynamic Layer 3 routing.

OSPF can automatically exchange routing information between compatible routers and Layer 3 switches.

IPv4 & IPv6 Routing

NetVanta 1760 switches support both IPv4 and IPv6 routing functionality for organizations maintaining dual-stack or next-generation network environments.

Inter-VLAN Routing

Layer 3 switching allows the NetVanta 1760 Series to route traffic between VLANs without requiring all local traffic to pass through an external router.

This can simplify network designs containing separate:

  • User VLANs
  • Server VLANs
  • Voice VLANs
  • Security-camera VLANs
  • IoT VLANs
  • Management VLANs

ADTRAN NetVanta 1700 VLAN Support

The NetVanta 1760 Series supports IEEE 802.1Q VLAN switching and trunking.

ADTRAN documentation specifies support for thousands of VLANs on the current platform, making the switches suitable for complex segmented enterprise networks.

VLAN Trunking

VLAN trunking allows multiple logical networks to share one physical switch connection.

Trunk links are commonly used between:

  • Switches
  • Routers
  • Firewalls
  • Virtualization hosts
  • Other network infrastructure

ADTRAN Voice VLAN Support

NetVanta 1760 switches support voice VLAN functionality that can help separate and prioritize compatible VoIP traffic.

ADTRAN Quality of Service

Quality of Service helps administrators prioritize important traffic when multiple applications compete for network bandwidth.

NetVanta 1760 QoS functionality includes support for:

  • 802.1p priority
  • DSCP
  • Multiple hardware queues
  • Strict priority scheduling
  • Weighted Round Robin
  • Traffic policing
  • Traffic shaping

NetVanta 1760 for VoIP

Although the NetVanta 1760 Series is primarily an aggregation and high-speed switching platform, its QoS and voice-VLAN functionality can support converged voice networks.

ADTRAN Link Aggregation

The NetVanta 1760 Series supports standards-based link aggregation.

Link aggregation can combine multiple physical Ethernet interfaces into one logical connection.

Benefits can include:

  • Greater aggregate bandwidth
  • Link redundancy
  • Improved resilience

LACP on ADTRAN Switches

Link Aggregation Control Protocol allows compatible equipment to negotiate and manage aggregated Ethernet connections dynamically.

LACP can be useful for switch uplinks, servers, and network appliances.

ADTRAN Spanning Tree Support

NetVanta 1760 switches support multiple standards for preventing Layer 2 network loops.

Supported technologies include:

  • Spanning Tree Protocol
  • Rapid Spanning Tree Protocol
  • Multiple Spanning Tree Protocol

Rapid Spanning Tree

Rapid Spanning Tree can converge more quickly than traditional Spanning Tree when network topology changes.

Multiple Spanning Tree

Multiple Spanning Tree allows different VLAN groups to use separate spanning-tree instances for more flexible Layer 2 network design.

Ethernet Ring Protection Switching

The NetVanta 1760 Series supports G.8032 Ethernet Ring Protection Switching.

ERPS is designed to provide rapid network recovery in compatible Ethernet ring topologies.

This can be particularly useful in:

  • Campus networks
  • Multi-building environments
  • Industrial networks
  • Fiber-ring architectures

ADTRAN High-Availability Switching

High availability requires more than raw port speed.

NetVanta 1760 infrastructure supports technologies that can improve network resilience, including:

  • Link aggregation
  • Spanning Tree
  • ERPS
  • Dynamic routing
  • Redundant power on the 1760-12F

NetVanta 1760-12F Redundant Power

The NetVanta 1760-12F supports an optional secondary hot-swappable AC power supply.

Adding the second supported PSU can reduce dependence on a single internal power supply.

Hummingbird Networks currently carries the compatible NetVanta 1760-12F power supply.

NetVanta 1760 Hot-Swappable Power Supply

Hot-swappable power allows a failed supply to be replaced under supported conditions while the second power supply keeps the switch operating.

This can improve serviceability in critical enterprise environments.

NetVanta 1760-12F Power Supply Part Number

The optional redundant AC power supply for the NetVanta 1760-12F is ADTRAN part number 17101760PF1.

Always verify compatibility before ordering replacement or redundant power components.

NetVanta 1760 Switching Performance

The two current NetVanta 1760 models provide different switching capacities.

NetVanta 1760-8F: Up to 200 Gbps switching performance.

NetVanta 1760-12F: Up to 340 Gbps switching performance.

Non-Blocking Layer 2 & Layer 3 Switching

ADTRAN designed the 1760 family around non-blocking Layer 2 and Layer 3 switching to support high-bandwidth enterprise traffic.

NetVanta 1760 MAC Address Capacity

Current ADTRAN specifications provide support for a large MAC address table suitable for enterprise switching environments.

This helps the platform support many connected devices across aggregated network segments.

NetVanta 1760 Jumbo Frames

The NetVanta 1760 Series supports jumbo Ethernet frames.

Jumbo frames can be useful in selected:

  • Server networks
  • Storage networks
  • Virtualized environments
  • High-throughput data transfers

Every device in the path should support the configured frame size.

ADTRAN NetVanta 1700 Security Features

NetVanta 1760 switches include enterprise security features for protecting switch management and controlling network access.

Capabilities include:

  • 802.1X authentication
  • MAC-based port security
  • Access control lists
  • RADIUS
  • TACACS+
  • SSH
  • ARP inspection
  • Denial-of-service protection

802.1X Authentication

802.1X allows compatible authentication infrastructure to verify a device or user before granting wired network access.

MAC-Based Port Security

MAC-based security can restrict which network devices are permitted to connect through particular switch ports.

Access Control Lists

ACLs allow administrators to define traffic policies according to network addresses and other packet characteristics.

ACLs can help enforce segmentation and traffic restrictions between network resources.

RADIUS & TACACS+

RADIUS and TACACS+ support can centralize authentication and authorization for network administration.

SSH Management

Secure Shell provides encrypted remote command-line administration for compatible NetVanta switching environments.

ADTRAN NetVanta 1700 Management

The NetVanta 1760 family provides several management options for enterprise administrators.

These include:

  • Command-line interface
  • Web-based graphical interface
  • SNMP
  • SSH
  • Centralized ADTRAN management platforms

ADTRAN Switch Web GUI

The NetVanta 1760 provides an intuitive browser-based management interface for administrators who prefer graphical configuration and monitoring.

ADTRAN Switch CLI

The command-line interface provides detailed configuration, troubleshooting, and network-administration capabilities.

ADTRAN SNMP Management

SNMP allows network-management platforms to monitor switch health, interface status, traffic, and other operating information.

ADTRAN n-Command Management

NetVanta 1760 switches can integrate with compatible ADTRAN n-Command management infrastructure.

Centralized management capabilities can include:

  • Device discovery
  • Configuration changes
  • Firmware upgrades
  • Configuration backup
  • Configuration restoration
  • Asset inventory reporting

ADTRAN NetVanta 1760 Diagnostics

Network diagnostics help administrators identify cabling, interface, optical, and traffic problems.

NetVanta 1760 diagnostic capabilities include:

  • Port mirroring
  • Flow mirroring
  • Ping
  • Traceroute
  • Cable diagnostics
  • SFP diagnostics
  • sFlow

ADTRAN SFP Diagnostics

Compatible optical transceivers can provide diagnostic information that helps administrators monitor optical performance and troubleshoot fiber links.

ADTRAN sFlow Support

sFlow provides traffic-sampling information that can help administrators understand network usage and traffic patterns.

NetVanta 1760 SFP+ Transceivers

The NetVanta 1760 family uses SFP+ ports for high-speed optical or compatible direct-attach connectivity.

Transceiver selection should consider:

  • Network speed
  • Fiber type
  • Wavelength
  • Connector
  • Required distance
  • ADTRAN compatibility

Explore Transceiver Modules for compatible optics.

NetVanta 1760 SFP28 Transceivers

The 1760-12F supports SFP28 interfaces capable of 25 Gigabit Ethernet.

Use compatible SFP28 optics or direct-attach connectivity designed for the required application.

Multimode Fiber for NetVanta 1760

Multimode optical transceivers can support high-speed short-distance fiber connections inside buildings, server rooms, and campus facilities.

Singlemode Fiber for NetVanta 1760

Singlemode optics can extend NetVanta 1760 connectivity over longer distances such as building-to-building and campus backbone links.

Explore Fiber Optic Cables when selecting the physical optical link.

DAC Cables for NetVanta 1760

Compatible Direct Attach Copper cables can provide cost-effective short-distance connectivity between supported SFP+ or SFP28 network interfaces.

DAC is particularly useful for connections within the same rack or between nearby equipment.

AOC Cables for NetVanta 1760

Active Optical Cables can provide longer integrated optical connections while retaining SFP-family direct-attach interfaces.

NetVanta 1760 for Campus Networks

The NetVanta 1760 family is well suited to campus aggregation because its fiber interfaces can consolidate traffic from multiple access switches and buildings.

Campus applications can include:

  • Building distribution
  • Fiber-ring networks
  • Access-switch aggregation
  • 10G campus backbones
  • 25G uplinks

NetVanta 1760 for Enterprise Networks

Enterprise networks can use NetVanta 1760 switching where conventional Gigabit uplinks no longer provide sufficient capacity.

High-speed connectivity can support:

  • Large user populations
  • Wireless networks
  • Voice
  • Video
  • Cloud applications
  • Servers
  • IoT

NetVanta 1760 for Server Connectivity

The 10G interfaces on NetVanta 1760 switches can connect compatible servers directly or aggregate traffic from server access infrastructure.

Explore Servers for compatible compute infrastructure.

NetVanta 1760 for Storage Networks

High-bandwidth Ethernet storage environments can use 10G or 25G connectivity where supported by both storage and switch infrastructure.

NetVanta 1760 for Wireless Aggregation

Modern WiFi networks can create substantial aggregate traffic across multiple access switches.

10G and 25G aggregation can help prevent lower-speed uplinks from becoming bottlenecks as wireless capacity increases.

NetVanta 1760 for Multi-Building Networks

Fiber-based NetVanta 1760 switching can aggregate links from multiple buildings or telecommunications rooms.

Singlemode fiber can provide substantial reach when buildings are separated by longer distances.

NetVanta 1760 for Data-Intensive Applications

ADTRAN positions the NetVanta 1760 family for bandwidth-intensive applications.

These can include:

  • Cloud applications
  • Large data transfers
  • Video
  • Storage
  • Server traffic
  • High-density network aggregation

NetVanta 1760-8F vs. 1760-12F

The two current NetVanta 1760 models address different network requirements.

NetVanta 1760-8F: Eight 10G SFP+ ports plus two multi-rate 10G RJ45 ports and up to 200 Gbps switching capacity.

NetVanta 1760-12F: Twelve 10G SFP+ ports plus two 25G SFP28 ports, up to 340 Gbps switching capacity, and support for redundant hot-swappable power.

Which NetVanta 1760 Should I Choose?

Choose the 1760-8F when:

  • Eight optical 10G ports are sufficient
  • 10G copper interfaces are useful
  • 25G uplinks are not required
  • A smaller aggregation platform fits the network

Choose the 1760-12F when:

  • More SFP+ port density is required
  • 25G uplinks are needed
  • Higher switching capacity is required
  • Redundant hot-swappable power is important

NetVanta 1700 vs. NetVanta 1500 Series

The NetVanta 1500 and 1700 families address different generations and performance requirements.

NetVanta 1500 Series: Primarily associated with Gigabit access switching, PoE, and selected 10G uplinks.

NetVanta 1700 Series: Focused on higher-bandwidth multigigabit aggregation and access with extensive 10G and 25G connectivity.

NetVanta 1560 vs. NetVanta 1760

The current NetVanta 1560 and 1760 families generally serve different roles.

NetVanta 1560: Gigabit access switching with PoE+ options and high-speed uplinks.

NetVanta 1760: Higher-bandwidth fiber aggregation and access switching using 10G and 25G interfaces.

When Should I Use a NetVanta 1760 Instead of a 1560?

A 1760 can be appropriate when the primary requirement is:

  • 10G fiber aggregation
  • Large quantities of optical interfaces
  • 25G uplinks
  • Higher switching throughput

A 1560 is generally better suited to connecting larger numbers of conventional Gigabit endpoint devices and providing PoE.

NetVanta 1760 & Access Switches

A common enterprise design can use NetVanta access switches for endpoint connectivity and NetVanta 1760 switching for aggregation.

This architecture can provide:

  • Gigabit endpoint access
  • PoE at the access layer
  • 10G access-switch uplinks
  • 25G aggregation uplinks

NetVanta 1760 Rack Installation

NetVanta 1760 switches can be installed in standard network racks and other supported mounting environments.

Rack planning should consider:

  • Airflow
  • Power
  • Fiber routing
  • DAC bend radius
  • Transceiver access
  • Cable management

NetVanta 1760 Cable Management

High-density SFP+ environments can contain many fiber or direct-attach cables in a small area.

Proper routing helps maintain:

  • Fiber bend radius
  • Port visibility
  • Airflow
  • Transceiver accessibility
  • Serviceability

Explore Cable Management for rack-routing products.

NetVanta 1760 Power Planning

Power planning should consider the switch itself and the surrounding rack infrastructure.

The 1760-12F can support a second hot-swappable AC power supply for improved redundancy.

NetVanta 1760 & UPS Systems

Critical aggregation switches can be connected to appropriately sized UPS infrastructure to maintain network operation during short utility-power interruptions.

NetVanta 1760 & Redundant Power Paths

For higher availability, dual switch power supplies should ideally connect to independent upstream power paths when the facility design permits.

A redundant architecture can include:

  • Dual power supplies
  • Separate power cords
  • Separate PDUs
  • Separate UPS systems
  • Independent circuits

Upgrading to NetVanta 1760

An organization may consider NetVanta 1760 switching when existing aggregation hardware is constrained by:

  • 1G uplinks
  • Limited 10G port density
  • Insufficient switching capacity
  • Lack of 25G connectivity
  • Limited redundancy

Planning a NetVanta 1760 Deployment

Before deploying the switch, document:

  • Number of required fiber links
  • Ethernet speed of each link
  • 10G copper requirements
  • 25G uplink requirements
  • Singlemode or multimode fiber
  • Transceiver requirements
  • Layer 3 routing
  • VLAN architecture
  • Link aggregation
  • Redundancy

How to Choose an ADTRAN NetVanta 1700 Series Switch

Determine Required Port Density

Identify the number of high-speed optical and copper links required.

Determine Whether 25G Is Required

If 25 Gigabit uplinks are required, the NetVanta 1760-12F provides SFP28 interfaces.

Identify Copper 10G Requirements

If the design requires high-speed RJ45 connectivity, the NetVanta 1760-8F provides two multi-rate copper interfaces.

Calculate Switching Capacity

Consider current and expected aggregate network traffic.

Determine Layer 3 Requirements

Identify static routing, OSPF, inter-VLAN routing, and IPv6 requirements.

Choose Optical Connectivity

Match SFP+ and SFP28 transceivers to speed, fiber type, wavelength, and distance.

Plan Redundancy

Consider links, routing, ring protection, and redundant power requirements.

ADTRAN NetVanta 1700 Series Selection Checklist

Before purchasing a NetVanta 1700 Series switch, verify:

  • Required 10G port count
  • Required 25G port count
  • RJ45 10G requirements
  • SFP+ requirements
  • SFP28 requirements
  • Singlemode or multimode fiber
  • Transceiver compatibility
  • Layer 3 routing requirements
  • VLAN requirements
  • QoS requirements
  • Link aggregation
  • Redundancy requirements
  • Power-supply redundancy
  • Switching-capacity requirements
  • Future bandwidth growth

Why Buy ADTRAN NetVanta 1700 Series Switches from Hummingbird Networks?

High-speed aggregation switching requires careful coordination between switches, transceivers, fiber, direct-attach cabling, routing, redundancy, and network topology.

Hummingbird Networks offers ADTRAN NetVanta 1700 Series switching and compatible connectivity for business and enterprise environments.

Customers can turn to our team for:

  • ADTRAN NetVanta 1700 Series switches
  • ADTRAN NetVanta 1760 switches
  • NetVanta 1760-8F
  • NetVanta 1760-12F
  • ADTRAN 10G switches
  • ADTRAN 25G switches
  • ADTRAN Layer 3 switches
  • ADTRAN fiber aggregation switches
  • SFP+ transceivers
  • SFP28 transceivers
  • Compatible fiber connectivity
  • DAC and AOC connectivity
  • NetVanta 1760 replacement and redundant power supplies
  • Product and compatibility guidance

Whether you need a compact NetVanta 1760-8F for high-speed fiber aggregation or a NetVanta 1760-12F with 25G uplinks and redundant-power capability, Hummingbird Networks can help identify ADTRAN switching and connectivity based on port density, Ethernet speed, fiber type, Layer 3 requirements, redundancy, and network architecture.

Frequently Asked Questions About ADTRAN NetVanta 1700 Series Switches

What is the ADTRAN NetVanta 1700 Series?

The NetVanta 1700 Series is ADTRAN's high-bandwidth managed switching family for multigigabit access and aggregation applications.

What ADTRAN NetVanta 1700 switches are available?

The current family is centered on the NetVanta 1760 Series, including the 1760-8F and 1760-12F.

What is the NetVanta 1760?

The NetVanta 1760 is a managed Layer 2 and Layer 3 multigigabit Ethernet switching family designed for high-performance aggregation and access applications.

What is the NetVanta 1760-8F?

The 1760-8F provides eight multi-rate SFP+ interfaces and two multi-rate RJ45 ports with speeds up to 10 Gigabit Ethernet.

What is the NetVanta 1760-12F?

The 1760-12F provides twelve multi-rate SFP+ ports and two SFP28 interfaces capable of up to 25 Gigabit Ethernet.

Does the NetVanta 1760 support Layer 3 switching?

Yes. The NetVanta 1760 family supports Layer 3 networking including static routing, RIP, OSPF, and inter-VLAN routing.

Does the NetVanta 1760 support 10 Gigabit Ethernet?

Yes. Both current 1760 models provide multiple 10G interfaces.

Does ADTRAN make a 25G switch?

Yes. The NetVanta 1760-12F includes two multi-rate SFP28 ports capable of 25 Gigabit Ethernet.

How many ports does the NetVanta 1760-8F have?

It includes eight multi-rate SFP+ ports plus two multi-rate RJ45 ports.

How many ports does the NetVanta 1760-12F have?

It includes twelve multi-rate SFP+ ports plus two multi-rate SFP28 ports.

What speeds do the NetVanta 1760 SFP+ ports support?

The multi-rate interfaces support multiple speeds including 1G, 2.5G, 5G, and 10G, with additional lower-rate support depending on the interface and configuration.

What is the switching capacity of the NetVanta 1760-8F?

ADTRAN rates the NetVanta 1760-8F for up to 200 Gbps of switching performance.

What is the switching capacity of the NetVanta 1760-12F?

ADTRAN rates the NetVanta 1760-12F for up to 340 Gbps of switching performance.

Does the NetVanta 1760-12F support redundant power?

Yes. It supports an optional second hot-swappable AC power supply.

Does Hummingbird Networks carry the NetVanta 1760-12F power supply?

Yes. Hummingbird Networks currently carries ADTRAN part number 17101760PF1 for compatible NetVanta 1760-12F redundant-power configurations.

Does the NetVanta 1760-8F support 10G copper?

Yes. It includes two multi-rate RJ45 ports capable of speeds up to 10 Gigabit Ethernet.

Does the NetVanta 1760 support VLANs?

Yes. The series supports IEEE 802.1Q VLAN switching and trunking.

Does the NetVanta 1760 support OSPF?

Yes. It supports OSPF routing on compatible software configurations.

Does the NetVanta 1760 support IPv6?

Yes. The platform supports IPv6 networking and routing functionality.

Does the NetVanta 1760 support link aggregation?

Yes. It supports standards-based Ethernet link aggregation.

Does the NetVanta 1760 support spanning tree?

Yes. Supported functionality includes traditional, Rapid, and Multiple Spanning Tree.

What is ERPS?

Ethernet Ring Protection Switching provides rapid failover in compatible Ethernet ring network designs.

Does the NetVanta 1760 support ERPS?

Yes. The current platform supports G.8032 Ethernet Ring Protection Switching.

Can the NetVanta 1760 use multimode fiber?

Yes, when compatible multimode SFP+ or SFP28 optics are used.

Can the NetVanta 1760 use singlemode fiber?

Yes, when compatible singlemode optical transceivers are installed.

Can the NetVanta 1760 use DAC cables?

Compatible direct-attach cables can be used for supported short-distance SFP-family connections.

Is the NetVanta 1760 suitable for campus networks?

Yes. Its high-density fiber connectivity, Layer 3 routing, redundancy features, and 10G/25G interfaces make it suitable for campus aggregation.

Is the NetVanta 1760 suitable for data centers?

It can support selected high-speed server, network, and aggregation applications where its interface density and switching capacity meet the design requirements.

Is the NetVanta 1760 a PoE switch?

No. The 1760 family is primarily a high-speed aggregation and fiber-access platform rather than a PoE endpoint-access switch.

Which ADTRAN switch should I use for PoE endpoints?

Current NetVanta 1560 and 1570 platforms are better suited to many Gigabit PoE access-layer deployments.

What is the difference between NetVanta 1560 and NetVanta 1760?

The 1560 is primarily a Gigabit PoE access family, while the 1760 focuses on multigigabit 10G and 25G aggregation and high-speed access.

What is the difference between the 1760-8F and 1760-12F?

The 1760-8F provides eight SFP+ ports plus two 10G RJ45 interfaces, while the 1760-12F provides twelve SFP+ ports, two 25G SFP28 interfaces, higher switching capacity, and redundant-power capability.

Does Hummingbird Networks sell the NetVanta 1760-8F?

Yes. Hummingbird Networks currently lists the ADTRAN NetVanta 1760-8F, part number 17101762F1.

Does Hummingbird Networks sell the NetVanta 1760-12F?

Yes. Hummingbird Networks currently lists the ADTRAN NetVanta 1760-12F, part number 17101763F1.

Can Hummingbird Networks help me choose between the 1760-8F and 1760-12F?

Yes. Providing the required 10G port count, 10G copper requirements, 25G requirements, fiber type, routing requirements, and redundancy needs can help determine the appropriate NetVanta 1760 model.

Shop ADTRAN NetVanta 1700 Series Switches

Build high-bandwidth business and enterprise networks with ADTRAN NetVanta 1700 Series managed switches for multigigabit aggregation, 10 Gigabit fiber networking, 25 Gigabit uplinks, Layer 3 routing, and resilient enterprise infrastructure.

From the compact NetVanta 1760-8F with SFP+ and 10G RJ45 connectivity to the higher-capacity NetVanta 1760-12F with twelve 10G SFP+ ports, dual 25G SFP28 uplinks, and optional redundant power, Hummingbird Networks can help organizations select ADTRAN switching based on bandwidth, port density, fiber, routing, redundancy, and network architecture.