Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.
5000VA UPS Smart Pro Rack/Tower Line-Interactive 5kVA 208/120V 11 outlets
This product is very heavy and normally ships on a pallet. Specific arrangements must be made with Hummingbird Networks to arrange delivery after order is submitted.
OUTPUT | |
Output Volt Amp Capacity (VA) | 5000 |
Output kVA capacity (kVA) | 5 |
Output Watt Capacity (watts) | 3750 |
Output kW capacity | 3.8 |
Output power factor | 0.8 |
Nominal Output Voltage(s) Supported | 120V; 208V |
Frequency compatibility | 60 Hz |
Output voltage regulation (line mode) | 208 & 120V (+/- 10%) |
Output voltage regulation (Battery mode) | +/- 5% |
Built-in UPS output receptacles | 8 5-15/20R outlet(s); 2 L6-20R outlet(s); 1 L6-30R outlet(s) |
Built-in controllable switched load banks | Eight switchable single-outlet 5-15/20R load banks |
Output circuit breaker | 20A double pole breaker supports L6-20R outlets, 20A branch rated breaker (x2) supports 4 5-15/20R outlets each, L6-30R outlet is unbreakered |
Output AC waveform (AC mode) | Sine wave |
Output AC waveform (battery mode) | Pure Sine wave |
INPUT | |
Rated input current (at maximum load) | 27A |
Nominal Input Voltage(s) Supported | 208V AC |
UPS input connection type | L6-30P |
UPS Input cord length (ft.) | 10 |
UPS Input cord length (m) | 3 |
Recommended Electrical Service | 30A 208V |
Phase | Single-Phase |
BATTERY | |
Full load runtime (minutes) | 8.5 min. (3750w) |
Half load runtime (minutes) | 20 min. (1875w) |
Expandable battery runtime | Extended runtime supported via optional external battery packs |
External battery pack compatibility | BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible) |
DC system voltage (VDC) | 48 |
Battery recharge rate (included batteries) | Less than 4 hours from 10% to 90% |
Replacement battery cartridge (internal UPS battery replacement) | RBC94-3U (quantity 3) |
Battery Access | Front panel battery access door |
Battery replacement description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 167 to 260 |
Overvoltage correction | Input voltages between 228 and 260 are reduced by 12% |
Undervoltage correction | Input voltages between 167 and 194 are boosted by 12% |
LEDS ALARMS & SWITCHES | |
LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
Alarms | Audible alarm indicates power-failure, overload and low-battery conditions |
Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression joule rating | 1020 |
UPS AC suppression response time | Instantaneous |
EMI / RFI AC noise suppression | Yes |
PHYSICAL | |
Installation form factors supported with included accessories | 4 post 19 inch rackmount |
Installation form factors supported with optional accessories | 2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND) |
Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 5.2 x 17.5 x 25 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 13.3 x 44.4 x 63.5 |
Rack Height | 3U |
Secondary form factor | Tower (requires 2-9USTAND) |
UPS / Power Module weight (lbs) | 143.3 |
UPS / Power Module weight (kg) | 65.1 |
UPS Shipping dimensions (height x width x depth / inches) | 11.2 x 23 x 31.5 |
UPS Shipping dimensions (height x width x depth / cm) | 28.6 x 58.4 x 80 |
Shipping weight (lbs) | 181.9 |
Shipping weight (kg) | 82.6 |
Cooling method | Fan |
UPS housing material | Steel |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 67110% |
Battery mode BTU / hr. (full load) | 141670% |
AC mode efficiency rating (100% load) | 97% |
COMMUNICATIONS | |
Communications interface | USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
Network monitoring port description | Supports detailed monitoring of UPS and site power conditions |
PowerAlert software | Included |
Communications cable | USB and DB9 cabling included |
WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER | |
Transfer time | 2-4 milliseconds |
Low voltage transfer to battery power (setpoint) | 167 |
High voltage transfer to battery power (setpoint) | 260 |
SPECIAL FEATURES | |
Grounding lug | Back panel grounding lug |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
High availability UPS features | Hot swappable batteries |
Green & high efficiency features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) |
WARRANTY | |
Product Warranty Period (Worldwide) | 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |