| OUTPUT | |
| Output Volt Amp Capacity (VA) | 2200 |
| Output kVA capacity (kVA) | 2.2 |
| Output Watt Capacity (watts) | 1900 |
| Output kW capacity | 1.9 |
| Nominal Output Voltage(s) Supported | 120V |
| Frequency compatibility | 60 Hz |
| Output voltage regulation (line mode) | -18%, +8% |
| Output voltage regulation (Battery mode) | +/- 5% |
| Built-in UPS output receptacles | 4 5-15R outlet(s); 4 5-15/20R outlet(s) |
| Built-in controllable switched load banks | Three switchable single-outlet 5-15R load banks |
| Output AC waveform (AC mode) | Sine wave |
| Output AC waveform (battery mode) | Pure Sine wave |
| INPUT | |
| Rated input current (at maximum load) | 16A |
| Nominal Input Voltage(s) Supported | 120V AC |
| UPS input connection type | 5-20P |
| Input circuit breaker | 20A |
| UPS Input cord length (ft.) | 10 |
| UPS Input cord length (m) | 3 |
| Recommended Electrical Service | 20A 120V |
| Phase | Single-Phase |
| BATTERY | |
| Full load runtime (minutes) | 11 min. (1900w) |
| Half load runtime (minutes) | 28 min. (950w) |
| Expandable battery runtime | Extended runtime supported via optional external battery packs |
| External battery pack compatibility | BP48V24-2U (limit 1); BP48V48RT4U (multi-pack compatible); BP48V27-2US (multi-pack compatible) |
| DC system voltage (VDC) | 48 |
| Battery recharge rate (included batteries) | Less than 3.6 hours from 10% to 90% |
Replacement battery cartridge (internal UPS battery replacement) | RBC94-2U (quantity 2) |
| Battery Access | Front panel battery access door |
| Battery replacement description | Hot-swappable, user replaceable batteries |
| VOLTAGE REGULATION | |
| Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145 |
| Overvoltage correction | Input voltages between 127 and 145 are reduced by 12% |
| Undervoltage correction | Input voltages between 96 and 108 are boosted by 12% |
| Severe undervoltage correction | Input voltages between 83 and 95 are boosted by 24% |
| LEDS ALARMS & SWITCHES | |
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
| Alarms | Audible alarm indicates power-failure, overload and low-battery conditions |
| Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support low/high charger settings |
| SURGE / NOISE SUPPRESSION | |
| UPS AC suppression joule rating | 570 |
| UPS AC suppression response time | Instantaneous |
| EMI / RFI AC noise suppression | Yes |
| PHYSICAL | |
Installation form factors supported with included accessories | 2 post 19 inch rackmount |
Installation form factors supported with optional accessories | 4 post rackmount (4POSTRAILKIT); Tower (2-9USTAND) |
| Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 6.89 x 17.3 x 17.8 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 17.5 x 43.9 x 45.2 |
| Rack Height | 4U |
| Secondary form factor | Tower (requires 2-9USTAND) |
| UPS / Power Module weight (lbs) | 100.3 |
| UPS / Power Module weight (kg) | 45.5 |
UPS Shipping dimensions (height x width x depth / inches) | 12.8 x 23.3 x 22.8 |
UPS Shipping dimensions (height x width x depth / cm) | 32.4 x 59.1 x 57.8 |
| Shipping weight (lbs) | 128.9 |
| Shipping weight (kg) | 58.5 |
| Cooling method | Fan |
| UPS housing material | Steel |
| ENVIRONMENTAL | |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity | 0 to 95%, non-condensing |
| AC mode BTU / hr. (full load) | 24200% |
| AC mode efficiency rating (100% load) | 97% |
| COMMUNICATIONS | |
| Communications interface | USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
| Network monitoring port description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert software | Included |
| Communications cable | USB and DB9 cabling included |
| WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| LINE / BATTERY TRANSFER | |
| Transfer time | 5 milliseconds |
| Low voltage transfer to battery power (setpoint) | 83 |
| High voltage transfer to battery power (setpoint) | 145 |
| SPECIAL FEATURES | |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
| High availability UPS features | Hot swappable batteries |
| CERTIFICATIONS | |
| UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) |
| WARRANTY | |
| Product Warranty Period (U.S. & Canada) | 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
| Product Warranty Period (International) | 2-year limited warranty |
| Product Warranty Period (Mexico) | 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
| Product Warranty Period (Puerto Rico) | 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |