Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.
Share:
500VA UPS OMNI Tower Full Isolation AVR Line-Interactive 6 outlet
Key Features
- 500VA line-interactive UPS with faraday-shielded, low-impedance isolation transformer delivers full isolation from potential damage and performance problems
- Provides immunity from EMI/RFI line noise in both normal and common modes. Delivers clean signal-reference ground, reducing data errors and audio/video distortion
- Automatic voltage regulation (AVR) automatically corrects incoming voltage to keep equipment working through low voltage (brownouts) as low as 83V, without draining battery power
- Supports loads up to 500VA/300W
- 5.4 min. full-load runtime (300W); 11 min. half load runtime (150W)
- Electrostatic discharge (ESD) resistance reduces potential static damage to connected electronics
- Built-in USB port and PowerAlert Software (free via web download) provide safe, unattended system shutdown during extended blackouts
- Built-in surge suppression (backed by $200,000 Ultimate Lifetime Insurance) safeguards connected equipment against damage
- SURGE VOLTAGE WITHSTAND CAPABILITY: ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave.
- SURGE VOLTAGE ATTENUATION: N-G 2000:1, L-G 240:1, L-N 100:1.
- INSERTION LOSS: 65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500 Khz.
- 3 protected outlets; 6-ft. cord
- 4 diagnostic LEDs indicate AC present, on battery, overload and battery low/replace
Package Includes
- OMNI500ISO UPS system
- USB cable
- Instruction manual
OUTPUT | |
Output Volt Amp Capacity (VA) | 500 |
Output Watt Capacity (watts) | 300 |
Output power factor | 0.6 |
Nominal Output Voltage(s) Supported | 115V; 120V |
Frequency compatibility | 60 Hz |
Output voltage regulation (line mode) | -18%, +8% |
Output voltage regulation (Battery mode) | 115V (+/- 5%) |
Built-in UPS output receptacles | 3 5-15R outlet(s) |
Output AC waveform (AC mode) | Sine wave |
Output AC waveform (battery mode) | PWM sine wave |
INPUT | |
Rated input current (at maximum load) | 4.8A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS input connection type | 5-15P |
UPS Input cord length (ft.) | 6 |
UPS Input cord length (m) | 1.8 |
Recommended Electrical Service | 15A 120V |
Phase | Single-Phase |
BATTERY | |
Full load runtime (minutes) | 5.4 min. (300w) |
Half load runtime (minutes) | 11 min. (150w) |
DC system voltage (VDC) | 12 |
Battery recharge rate (included batteries) | Less than 4.5 hours from 10% to 90% |
Replacement battery cartridge (internal UPS battery replacement) | RBC51 |
Battery Access | Battery access door |
Battery replacement description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 83 |
Undervoltage correction | Input voltages between 83 and 107 are boosted by 14% |
LEDS ALARMS & SWITCHES | |
LED Indicators | 4 LEDs indicate line power, battery power, overload and battery low/replace status |
Alarms | Audible alarm indicates power-failure and low-battery conditions |
Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression joule rating | 680 |
UPS AC suppression response time | Instantaneous |
EMI / RFI AC noise suppression | Yes |
ISOLATION | |
Output isolation transformer | Professional grade load isolation transformer |
Surge voltage withstand capability | ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave |
Surge voltage attenuation | N-G 2000:1, L-G 240:1, L-N 100:1 |
Insertion loss | 65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500 Khz |
PHYSICAL | |
Installation form factors supported with included accessories | Tower |
Installation form factors supported with optional accessories | Wallmount (UPSWM - tower mounting kit) |
Primary form factor | Tower |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 10.8 x 5.2 x 7.5 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 27.3 x 13.3 x 19 |
UPS / Power Module weight (lbs) | 21.8 |
UPS / Power Module weight (kg) | 9.9 |
UPS Shipping dimensions (height x width x depth / inches) | 14 x 8.5 x 11 |
UPS Shipping dimensions (height x width x depth / cm) | 35.6 x 21.6 x 27.9 |
Shipping weight (lbs) | 27 |
Shipping weight (kg) | 12.3 |
UPS housing material | PVC |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 100.9 |
Battery mode BTU / hr. (full load) | 223.9 |
AC mode efficiency rating (100% load) | 91% |
COMMUNICATIONS | |
Communications interface | USB |
PowerAlert software | Free download from www.tripplite.com |
Communications cable | USB cable included |
WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER | |
Transfer time | 2-4 milliseconds |
Low voltage transfer to battery power (setpoint) | 83 |
High voltage transfer to battery power (setpoint) | 147 |
SPECIAL FEATURES | |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
High availability UPS features | Hot swappable batteries |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI) |
WARRANTY | |
Product Warranty Period (Worldwide) | 2-year limited warranty |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $200,000 Ultimate Lifetime Insurance |