Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.
Forget chasing down reps or emailing into the abyss. Get your own IT Concierge — a real human who stays with you from start to finish. One point of contact. Zero runaround.
Under the gun? We turn around Cisco & Meraki quotes in record time — even complex builds. No waiting days for basic pricing.
Need to validate your BoM or double-check your plan? Our Cisco-certified engineers review it with you, optimize where needed, and catch gotchas before they cost you…all free.
Pre-config, licensing help, and install guidance — we make sure what you buy solves your problem, the first time.
Turn your old gear into instant quote credits. We can coordinate the recycling or destruction in an environmentally friendly and safe manner. Enjoy a smoother path to your upgrade with built-in savings.
Get access to exclusive Cisco/Meraki incentives, special pricing tiers, and project-based discounts you won’t find anywhere else.
Want to skip the back and forth? Talk directly to a specialist and get expert guidance in under 30 minutes.
2200VA UPS Compact 4U RM Smart Pro Line-Interactive 8 outlets 120V
This product is very heavy and normally ships on a pallet. Specific arrangements must be made with Hummingbird Networks to arrange delivery after order is submitted.
| OUTPUT | |
| Output Volt Amp Capacity (VA) | 2200 |
| Output kVA capacity (kVA) | 2.2 |
| Output Watt Capacity (watts) | 1900 |
| Output kW capacity | 1.9 |
| Nominal Output Voltage(s) Supported | 120V |
| Frequency compatibility | 60 Hz |
| Output voltage regulation (line mode) | -18%, +8% |
| Output voltage regulation (Battery mode) | +/- 5% |
| Built-in UPS output receptacles | 4 5-15R outlet(s); 4 5-15/20R outlet(s) |
| Built-in controllable switched load banks | Three switchable single-outlet 5-15R load banks |
| Output AC waveform (AC mode) | Sine wave |
| Output AC waveform (battery mode) | Pure Sine wave |
| INPUT | |
| Rated input current (at maximum load) | 16A |
| Nominal Input Voltage(s) Supported | 120V AC |
| UPS input connection type | 5-20P |
| Input circuit breaker | 20A |
| UPS Input cord length (ft.) | 10 |
| UPS Input cord length (m) | 3 |
| Recommended Electrical Service | 20A 120V |
| Phase | Single-Phase |
| BATTERY | |
| Full load runtime (minutes) | 11 min. (1900w) |
| Half load runtime (minutes) | 28 min. (950w) |
| Expandable battery runtime | Extended runtime supported via optional external battery packs |
| External battery pack compatibility | BP48V24-2U (limit 1); BP48V48RT4U (multi-pack compatible); BP48V27-2US (multi-pack compatible) |
| DC system voltage (VDC) | 48 |
| Battery recharge rate (included batteries) | Less than 3.6 hours from 10% to 90% |
| Replacement battery cartridge (internal UPS battery replacement) | RBC94-2U (quantity 2) |
| Battery Access | Front panel battery access door |
| Battery replacement description | Hot-swappable, user replaceable batteries |
| VOLTAGE REGULATION | |
| Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145 |
| Overvoltage correction | Input voltages between 127 and 145 are reduced by 12% |
| Undervoltage correction | Input voltages between 96 and 108 are boosted by 12% |
| Severe undervoltage correction | Input voltages between 83 and 95 are boosted by 24% |
| LEDS ALARMS & SWITCHES | |
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
| Alarms | Audible alarm indicates power-failure, overload and low-battery conditions |
| Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support low/high charger settings |
| SURGE / NOISE SUPPRESSION | |
| UPS AC suppression joule rating | 570 |
| UPS AC suppression response time | Instantaneous |
| EMI / RFI AC noise suppression | Yes |
| PHYSICAL | |
| Installation form factors supported with included accessories | 2 post 19 inch rackmount |
| Installation form factors supported with optional accessories | 4 post rackmount (4POSTRAILKIT); Tower (2-9USTAND) |
| Primary form factor | Rackmount |
| UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 6.89 x 17.3 x 17.8 |
| UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 17.5 x 43.9 x 45.2 |
| Rack Height | 4U |
| Secondary form factor | Tower (requires 2-9USTAND) |
| UPS / Power Module weight (lbs) | 100.3 |
| UPS / Power Module weight (kg) | 45.5 |
| UPS Shipping dimensions (height x width x depth / inches) | 12.8 x 23.3 x 22.8 |
| UPS Shipping dimensions (height x width x depth / cm) | 32.4 x 59.1 x 57.8 |
| Shipping weight (lbs) | 128.9 |
| Shipping weight (kg) | 58.5 |
| Cooling method | Fan |
| UPS housing material | Steel |
| ENVIRONMENTAL | |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity | 0 to 95%, non-condensing |
| AC mode BTU / hr. (full load) | 24200% |
| AC mode efficiency rating (100% load) | 97% |
| COMMUNICATIONS | |
| Communications interface | USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
| Network monitoring port description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert software | Included |
| Communications cable | USB and DB9 cabling included |
| WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| LINE / BATTERY TRANSFER | |
| Transfer time | 5 milliseconds |
| Low voltage transfer to battery power (setpoint) | 83 |
| High voltage transfer to battery power (setpoint) | 145 |
| SPECIAL FEATURES | |
| Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
| High availability UPS features | Hot swappable batteries |
| CERTIFICATIONS | |
| UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) |
| WARRANTY | |
| Product Warranty Period (U.S. & Canada) | 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
| Product Warranty Period (International) | 2-year limited warranty |
| Product Warranty Period (Mexico) | 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
| Product Warranty Period (Puerto Rico) | 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
| Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |