2600VA UPS Smart Pro Rack/Tower Line-Interactive 9 outlet
OUTPUT | |
Output Volt Amp Capacity (VA) | 2600 |
Output kVA capacity (kVA) | 2.6 |
Output Watt Capacity (watts) | 2100 |
Output kW capacity | 2.1 |
Output power factor | 0.8 |
Nominal Output Voltage(s) Supported | 120V |
Frequency compatibility | 60 Hz |
Output voltage regulation (line mode) | -18%, +8% |
Output voltage regulation (Battery mode) | +/- 5% |
Built-in UPS output receptacles | 4 5-15R outlet(s); 4 5-15/20R outlet(s); 1 L5-20R outlet(s) |
Built-in controllable switched load banks | Three switchable single-outlet 5-15R load banks |
Output circuit breaker | 15A breaker protects 5-15R, 20A breaker protects 5-15/20R, L5-20R is unbreakered |
Output AC waveform (AC mode) | Sine wave |
Output AC waveform (battery mode) | Pure Sine wave |
INPUT | |
Rated input current (at maximum load) | 24A (with user-supplied L5-30P plug), 16A (with factory 5-20P plug) |
Nominal Input Voltage(s) Supported | 120V AC |
UPS input connection type | 5-20P |
Input circuit breaker | 30A |
UPS Input cord length (ft.) | 10 |
UPS Input cord length (m) | 3 |
Recommended Electrical Service | 20A 120V |
Phase | Single-Phase |
BATTERY | |
Full load runtime (minutes) | 4 min. (2100w) |
Half load runtime (minutes) | 11 min. (1050w) |
Expandable battery runtime | Extended runtime supported via optional external battery packs |
External battery pack compatibility | BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible) |
DC system voltage (VDC) | 48 |
Battery recharge rate (included batteries) | Less than 4.5 hours from 10% to 90% |
Replacement battery cartridge (internal UPS battery replacement) | RBC94-2U |
Battery Access | Front panel battery access door |
Battery replacement description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147 |
Overvoltage correction | Input voltages between 127 and 147 are reduced by 12% |
Undervoltage correction | Input voltages between 95 and 104 are boosted by 12% |
Severe undervoltage correction | Input voltages between 83 and 94 are boosted by 24% |
LEDS ALARMS & SWITCHES | |
LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
Alarms | Audible alarm indicates power-failure, overload and low-battery conditions |
Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression joule rating | 480 |
UPS AC suppression response time | Instantaneous |
EMI / RFI AC noise suppression | Yes |
PHYSICAL | |
Installation form factors supported with optional accessories | 2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) |
Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 3.5 x 17.5 x 19 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 8.9 x 44.4 x 48.3 |
Rack Height | 2U |
Secondary form factor | Tower (requires 2-9USTAND) |
UPS / Power Module weight (lbs) | 64 |
UPS / Power Module weight (kg) | 29.1 |
UPS Shipping dimensions (height x width x depth / inches) | 9 x 23.5 x 20 |
UPS Shipping dimensions (height x width x depth / cm) | 22.9 x 59.7 x 50.8 |
Shipping weight (lbs) | 72 |
Shipping weight (kg) | 32.7 |
Cooling method | Fan |
UPS housing material | Steel |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 297.5 |
Battery mode BTU / hr. (full load) | 136000% |
AC mode efficiency rating (100% load) | 96% |
COMMUNICATIONS | |
Communications interface | USB (HID enabled); DB9 Serial; Contact closure |
Network monitoring port description | Supports detailed monitoring of UPS and site power conditions; 1 USB port and 1 DB9 serial contact closure port |
PowerAlert software | Included |
Communications cable | USB and DB9 cabling included |
WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER | |
Transfer time | 5 milliseconds |
Low voltage transfer to battery power (setpoint) | 83 |
High voltage transfer to battery power (setpoint) | 145 |
SPECIAL FEATURES | |
Grounding lug | Back panel grounding lug |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
High availability UPS features | Hot swappable batteries |
Green & high efficiency features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) |
WARRANTY | |
Product Warranty Period (Worldwide) | 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |