Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.
Hear What Our Customers Are Saying
-
20+ Years Experience Helping IT Heroes
Take advantage of 20+ years of expertise from a partner with available resources for large deployments, multi-site projects, and complex IT initiatives. We have the team to get the job done. -
Free Solution Design With White Glove Engineers
Solutions architects and project engineers will help you envision a successful outcome and give you personalized recommendations based on your unique needs. Free. Apply today. -
Configuration & Installation Services
Let us take care of configuring and installing your equipment so you can get back to business. Available nationwide. Apply today. -
Equipment Trade-In Program
Refreshing old hardware? Let us coordinate the recycling or destruction in an environmentally friendly and safe manner. As a bonus, working with us gives you access to specific trade-in discounts towards your network refresh. Apply today. -
Exclusive Incentives, Special Pricing, & Financing
After helping you build and validate your solution, we’ll include any applicable discounts, financing, and incentives applied to your project to guarantee you get the most value out of your IT investments through Hummingbird Networks. Apply today.
- Isolated cooling circuit
A separate, isolated section which houses all cooling components minimizes the risk of water contacting installed IT equipment in the unlikely event of a leak. - Front service access
The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side. - Top and bottom chilled water connections
It allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor. - Coolant balancing
It provides a central point for fluid balancing. - Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture. - Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy. - Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment. - Top and bottom chilled water connections
It allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor. - Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided. - Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods. - Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures. - Modular design
Modular design provides scalable solutions to add cooling as demand increases. - Scaleable densities
It allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures. - Casters
It provides flexibility to move the unit to wherever cooling is required. - Easy service access
It allows for all serviceable components to be replaced/maintained by easily accessible panels/doors. - Real-time capacity monitoring
Real-time display of current and available cooling. - Microprocessor controller
It provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display. - Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
The InRow chilled water product design closely couples the cooling with the IT heat load. This design prevents hot air recirculation, while improving cooling predictability and allowing for a pay as you grow environment. Data center operators looking to improve efficiency or deploy high density servers will benefit from the modular design of the InRow chilled water products. The intelligent controls of the InRow chilled water products actively adjust fan speed and chilled water flow to match the IT heat load to maximize efficiency and address the dynamic demands of today's IT environments.